CVE-2024-33500
A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.11.0), Mendix Applications using Mendix 10 (V10.6) (All versions < V10.6.9), Mendix Applications using Mendix 9 (All versions >= V9.3.0 < V9.24.22). Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.30%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-269
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-33500",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-33500",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-08-20T16:28:31.756301Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 0.7
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.4,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Mendix Applications using Mendix 10",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V10.11.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Mendix Applications using Mendix 10 (V10.6)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V10.6.9",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Mendix Applications using Mendix 9",
"versions": [
{
"status": "affected",
"version": "V9.3.0",
"lessThan": "V9.24.22",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "mendix",
"versions": [
{
"status": "affected",
"version": "10..0",
"lessThan": "10.11.0",
"versionType": "custom"
},
{
"status": "affected",
"version": "10.6",
"lessThan": "10.6.9",
"versionType": "custom"
},
{
"status": "affected",
"version": "9.3.0",
"lessThan": "9.24.22",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-06-11T12:15:15.957",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-540640.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-540640.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.11.0), Mendix Applications using Mendix 10 (V10.6) (All versions < V10.6.9), Mendix Applications using Mendix 9 (All versions >= V9.3.0 < V9.24.22). Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Aplicaciones Mendix que usan Mendix 10 (Todas las versiones < V10.11.0), Aplicaciones Mendix que usan Mendix 10 (V10.6) (Todas las versiones < V10.6.9), Aplicaciones Mendix que usan Mendix 9 (Todas las versiones >= V9 .3.0 < V9.24.22). Las aplicaciones afectadas podrían permitir a los usuarios con la capacidad de gestionar una función elevar los derechos de acceso de los usuarios con esa función. La explotación exitosa requiere adivinar la identificación de una función de destino que contiene derechos de acceso elevados."
}
],
"lastModified": "2026-06-17T07:31:52.227",
"sourceIdentifier": "productcert@siemens.com"
}