« Volver al listado

CVE-2024-32852

Estado: ModificadaAlta (7.5)—

Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.0 contain use of a broken or risky cryptographic algorithm vulnerability. An unprivileged network malicious attacker could potentially exploit this vulnerability, leading to data leaks.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-32852",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-32852",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-07-02T14:38:25.543010Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security_alert@emc.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "security_alert@emc.com",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerScale OneFS",
          "versions": [
            {
              "status": "affected",
              "version": "8.2.2.x",
              "versionType": "semver",
              "lessThanOrEqual": "9.5.0.8"
            },
            {
              "status": "affected",
              "version": "8.2.2.x",
              "versionType": "semver",
              "lessThanOrEqual": "9.7.0.0"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:dell:powerscale_onefs:8.2.2:*:*:*:*:*:*:*"
          ],
          "vendor": "dell",
          "product": "powerscale_onefs",
          "versions": [
            {
              "status": "affected",
              "version": "8.2.2",
              "versionType": "custom",
              "lessThanOrEqual": "9.7.0.0"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2024-07-02T07:15:03.103",
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000226569/dsa-2024-255-security-update-for-dell-powerscale-onefs-for-multiple-security-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "security_alert@emc.com"
    },
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000226569/dsa-2024-255-security-update-for-dell-powerscale-onefs-for-multiple-security-vulnerabilities",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security_alert@emc.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.0 contain use of a broken or risky cryptographic algorithm vulnerability. An unprivileged network malicious attacker could potentially exploit this vulnerability, leading to data leaks."
    },
    {
      "lang": "es",
      "value": "Dell PowerScale OneFS versiones 8.2.2.x a 9.7.0.0 contienen el uso de una vulnerabilidad de algoritmo criptográfico roto o riesgoso. Un atacante malicioso de red sin privilegios podría explotar esta vulnerabilidad y provocar fugas de datos."
    }
  ],
  "lastModified": "2026-06-17T07:30:33.000",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "921FDB32-8AD5-4899-B8C3-97C647D87FF5",
              "versionEndExcluding": "9.5.1.0",
              "versionStartIncluding": "8.2.0"
            },
            {
              "criteria": "cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5EF81235-CB35-43A4-A1F3-3ADE921BCDB4",
              "versionEndExcluding": "9.7.1.0",
              "versionStartIncluding": "9.6.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "security_alert@emc.com"
}