CVE-2024-32639
Status: DeferredHigh (7.8)—
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Base score: 7.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.42%
- Percentile among all scored CVEs: 34
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-787
References
Raw JSON (NVD)
Show
{
"id": "CVE-2024-32639",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-32639",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-28T19:50:12.033377Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2302",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2302.0011",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:2302.0011:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "tecnomatix_plant_simulation",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2302.0011",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-14T16:17:07.657",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-923361.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-923361.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2302 (Todas las versiones < V2302.0011). La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo MODEL especialmente manipulado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-22974)"
}
],
"lastModified": "2026-06-17T07:30:00.450",
"sourceIdentifier": "productcert@siemens.com"
}