« Volver al listado

CVE-2024-32291

Estado: AnalizadaAlta (7.5)—

Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-32291",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-32291",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-05-10T18:52:39.519156Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*"
          ],
          "vendor": "tenda",
          "product": "w30e",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
          ],
          "vendor": "tenda",
          "product": "w30e_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.1.25\\(633\\)"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-04-17T14:15:09.010",
  "references": [
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromNatlimit.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromNatlimit.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function."
    },
    {
      "lang": "es",
      "value": "El firmware v1.0.1.25(633) de Tenda W30E v1.0 tiene una vulnerabilidad de desbordamiento de pila a través del parámetro de página en la función fromNatlimit."
    }
  ],
  "lastModified": "2026-06-17T07:29:27.043",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "535AF764-B5CF-44FA-89C6-2FDFFDCD0A32"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "02FBE634-0D3F-4439-B4A6-F427C82967C7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}