CVE-2024-2813
Status: ModifiedCritical (9.8)—
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 9.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 1.31%
- Percentile among all scored CVEs: 70
- Score date: 10/7/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- CWE-121
References
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md
- https://vuldb.com/?ctiid.257668
- https://vuldb.com/?id.257668
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md
- https://vuldb.com/?ctiid.257668
- https://vuldb.com/?id.257668
Raw JSON (NVD)
Show
{
"id": "CVE-2024-2813",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-2813",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-08-23T20:28:00.506212Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "AC15",
"versions": [
{
"status": "affected",
"version": "15.03.20_multi"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "ac15_firmware",
"versions": [
{
"status": "affected",
"version": "15.03.05.20_multi"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-03-22T07:15:47.110",
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.257668",
"tags": [
"Permissions Required"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.257668",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.257668",
"tags": [
"Permissions Required"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.257668",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se encontró una vulnerabilidad en Tenda AC15 15.03.20_multi. Ha sido declarada crítica. Esta vulnerabilidad afecta a la función form_fast_setting_wifi_set del archivo /goform/fast_setting_wifi_set. La manipulación del argumento ssid provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257668. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T07:25:36.200",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}