« Volver al listado

CVE-2024-2726

Estado: AnalizadaMedia (6.1)—

Stored Cross-Site Scripting (Stored-XSS) vulnerability affecting the CIGESv2 system, allowing an attacker to execute and store malicious javascript code in the application form without prior registration.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-2726",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-2726",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-03-22T18:04:18.028373Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cve-coordination@incibe.es",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve-coordination@incibe.es",
      "affectedData": [
        {
          "vendor": "Ciges",
          "product": "CIGESv2",
          "versions": [
            {
              "status": "affected",
              "version": "CIGESv2"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2024-03-22T14:15:10.393",
  "references": [
    {
      "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-cigesv2-system",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve-coordination@incibe.es"
    },
    {
      "url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-cigesv2-system",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cve-coordination@incibe.es",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stored Cross-Site Scripting (Stored-XSS) vulnerability affecting the CIGESv2 system, allowing an attacker to execute and store malicious javascript code in the application form without prior registration."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de Cross-Site Scripting Almacenado (Stored-XSS) que afecta al sistema CIGESv2 y permite a un atacante ejecutar y almacenar código javascript malicioso en el formulario de la aplicación sin registro previo."
    }
  ],
  "lastModified": "2026-06-17T07:25:25.647",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:atisoluciones:ciges:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0B98131C-7B7E-4A5D-A1C0-B5597C729D64"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve-coordination@incibe.es"
}