« Volver al listado

CVE-2024-2704

Estado: AnalizadaAlta (8.8)—

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-2704",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-2704",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-12T15:19:20.302733Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Tenda",
          "product": "AC10U",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
          ],
          "vendor": "tenda",
          "product": "ac10u_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-03-20T16:15:08.640",
  "references": [
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetFirewallCfg.md",
      "tags": [
        "Exploit"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.257455",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.257455",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10U/v1.V15.03.06.49/more/formSetFirewallCfg.md",
      "tags": [
        "Exploit"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?ctiid.257455",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.257455",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Tenda AC10U 15.03.06.49 y clasificada como crítica. La función formSetFirewallCfg del archivo /goform/SetFirewallCfg es afectada por esta vulnerabilidad. La manipulación del argumento firewallEn conduce a un desbordamiento de búfer en la región stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257455. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
    }
  ],
  "lastModified": "2026-06-17T07:25:06.100",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}