« Back to list

CVE-2024-23795

Status: ModifiedHigh (7.8)—

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-23795",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-23795",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-08T15:45:37.675034Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2201",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2201.0012",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2302",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2302.0006",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-02-13T09:15:47.550",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones &lt; V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones &lt; V2302.0006). La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo WRL especialmente manipulado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."
    }
  ],
  "lastModified": "2026-06-17T07:13:37.037",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "92315B86-671A-48F9-9D7D-C638DABD8520",
              "versionEndExcluding": "2201.0012"
            },
            {
              "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D222D65A-C271-4BE4-8139-DB5F38D053D5",
              "versionEndExcluding": "2302.0006",
              "versionStartIncluding": "2302.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}