« Volver al listado

CVE-2024-22632

Estado: AplazadaCrítica (9.8)—

Setor Informatica Sistema Inteligente para Laboratorios (S.I.L.) 388 was discovered to contain a remote code execution (RCE) vulnerability via the hmsg parameter. This vulnerability is triggered via a crafted POST request.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-22632",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-22632",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-04-29T19:38:30.394967Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:setor:sil:388:*:*:*:*:*:*:*"
          ],
          "vendor": "setor",
          "product": "sil",
          "versions": [
            {
              "status": "affected",
              "version": "388"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-04-26T04:15:08.830",
  "references": [
    {
      "url": "https://tomiodarim.io/posts/cve-2024-22632-3/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://tomiodarim.io/posts/cve-2024-22632-3/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Setor Informatica Sistema Inteligente para Laboratorios (S.I.L.) 388 was discovered to contain a remote code execution (RCE) vulnerability via the hmsg parameter. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se descubrió que el Setor Informatica Sistema Inteligente para Laboratorios (SIL) 388 contenía una vulnerabilidad de ejecución remota de código (RCE) a través del parámetro hmsg. Esta vulnerabilidad se activa mediante una solicitud POST manipulada."
    }
  ],
  "lastModified": "2026-06-17T07:11:36.963",
  "sourceIdentifier": "cve@mitre.org"
}