« Volver al listado

CVE-2024-21914

Estado: AnalizadaMedia (5.3)—

A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-21914",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-21914",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-05T16:32:41.667546Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "FactoryTalk® View ME",
          "versions": [
            {
              "status": "affected",
              "version": "<v14"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:rockwellautomation:factorytalk_view_me:*:*:*:*:*:*:*:*"
          ],
          "vendor": "rockwellautomation",
          "product": "factorytalk_view_me",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "v14"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-03-25T22:37:19.627",
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1663.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "PSIRT@rockwellautomation.com"
    },
    {
      "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1663.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nA vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.\n\n"
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad en el producto afectado que permite a un usuario malintencionado reiniciar el terminal Rockwell Automation PanelView™ Plus 7 de forma remota sin protecciones de seguridad. Si se explota la vulnerabilidad, podría provocar la pérdida de visión o control del producto PanelView™."
    }
  ],
  "lastModified": "2026-06-17T07:10:24.190",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:machine:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8F2151E9-0310-4E7A-AA09-6BCD0C7232DF",
              "versionEndExcluding": "14.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}