« Volver al listado

CVE-2024-1606

Estado: AnalizadaMedia (5.4)—

Lack of input sanitization in BMC Control-M branches 9.0.20 and 9.0.21 allows logged-in users for manipulation of generated web pages via injection of HTML code. This might lead to a successful phishing attack for example by tricking users into using a hyperlink pointing to a website controlled by an attacker.

Fix for 9.0.20 branch was released in version 9.0.20.238. Fix for 9.0.21 branch was released in version 9.0.21.200.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-1606",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-1606",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-03-19T15:51:58.875820Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cvd@cert.pl",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.6,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.5,
        "exploitabilityScore": 2.1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 5.4,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.3
      }
    ]
  },
  "affected": [
    {
      "source": "cvd@cert.pl",
      "affectedData": [
        {
          "vendor": "BMC",
          "product": "Control-M",
          "versions": [
            {
              "status": "affected",
              "version": "9.0.20",
              "lessThan": "9.0.20.238",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "9.0.21",
              "lessThan": "9.0.21.200",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:bmc:control-m:-:*:*:*:*:*:*:*"
          ],
          "vendor": "bmc",
          "product": "control-m",
          "versions": [
            {
              "status": "affected",
              "version": "9.0.20",
              "lessThan": "9.0.20.238",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "9.0.21",
              "lessThan": "9.0.21.200",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-03-18T10:15:20.863",
  "references": [
    {
      "url": "https://cert.pl/en/posts/2024/03/CVE-2024-1604",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://cert.pl/posts/2024/03/CVE-2024-1604",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://www.bmc.com/it-solutions/control-m.html",
      "tags": [
        "Product"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://cert.pl/en/posts/2024/03/CVE-2024-1604",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert.pl/posts/2024/03/CVE-2024-1604",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.bmc.com/it-solutions/control-m.html",
      "tags": [
        "Product"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cvd@cert.pl",
      "description": [
        {
          "lang": "en",
          "value": "CWE-80"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Lack of input sanitization in BMC Control-M  branches 9.0.20 and 9.0.21 allows logged-in users for manipulation of generated  web pages via injection of  HTML code. This might lead to a successful phishing attack for example by tricking users into using a hyperlink pointing to a website controlled by an attacker.\n\nFix for 9.0.20 branch was released in version 9.0.20.238. Fix for 9.0.21 branch was released in version 9.0.21.200. \n\n"
    },
    {
      "lang": "es",
      "value": "La falta de sanitización de entradas en las ramas 9.0.20 y 9.0.21 de BMC Control-M permite a los usuarios registrados manipular las páginas web generadas mediante la inyección de código HTML. Esto podría conducir a un ataque de phishing exitoso, por ejemplo, engañando a los usuarios para que utilicen un hipervínculo que apunte a un sitio web controlado por un atacante. La solución para la rama 9.0.20 se lanzó en la versión 9.0.20.238. La solución para la rama 9.0.21 se lanzó en la versión 9.0.21.200."
    }
  ],
  "lastModified": "2026-06-17T07:04:37.663",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "87B57AF2-7AB2-48C3-A85B-A918033C70AF",
              "versionEndExcluding": "9.0.20.238",
              "versionStartIncluding": "9.0.20"
            },
            {
              "criteria": "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8F86D69B-93E8-42A3-8D24-CDB59F33A388",
              "versionEndExcluding": "9.0.21.201",
              "versionStartIncluding": "9.0.21"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cvd@cert.pl"
}