CVE-2024-1367
Estado: ModificadaAlta (7.2)—
A command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.56%
- Percentil entre todas las CVEs puntuadas: 74
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-1367",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-1367",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-02-15T20:05:10.392514Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "vulnreport@tenable.com",
"affectedData": [
{
"vendor": "Tenable",
"product": "Security Center",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.3.0",
"versionType": "6.3.0"
}
],
"platforms": [
"Linux"
],
"defaultStatus": "affected"
}
]
}
],
"published": "2024-02-14T22:15:47.753",
"references": [
{
"url": "https://www.tenable.com/security/tns-2024-02",
"tags": [
"Vendor Advisory"
],
"source": "vulnreport@tenable.com"
},
{
"url": "https://www.tenable.com/security/tns-2024-02",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\nA command injection vulnerability exists where an authenticated, remote attacker with administrator privileges on the Security Center application could modify Logging parameters, which could lead to the execution of arbitrary code on the Security Center host. \n\n"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de inyección de comandos donde un atacante remoto autenticado con privilegios de administrador en la aplicación Security Center podría modificar los parámetros de registro, lo que podría conducir a la ejecución de código arbitrario en el host de Security Center."
}
],
"lastModified": "2026-06-17T07:04:04.690",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tenable:security_center:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E4F24FE6-9C35-4B06-99E7-B38E07712148",
"versionEndExcluding": "6.3.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "vulnreport@tenable.com"
}