« Volver al listado

CVE-2024-12836

Estado: AnalizadaAlta (7.8)—

Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DRASimuCAD. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-22450.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L + UI:R indica ejecución en cliente (T1203). Apertura de archivo STP malicioso genera type confusion que causa RCE arbitraria (T1059).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-12836",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-12836",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-12-31T21:25:11.027822Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "zdi-disclosures@trendmicro.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.0",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "affectedData": [
        {
          "vendor": "Delta Electronics",
          "product": "DRASimuCAD",
          "versions": [
            {
              "status": "affected",
              "version": "1.02"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-12-30T17:15:08.137",
  "references": [
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1724/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "zdi-disclosures@trendmicro.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "zdi-disclosures@trendmicro.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-843"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Delta Electronics DRASimuCAD STP File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DRASimuCAD. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-22450."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de ejecución remota de código por confusión de tipos en el análisis de archivos STP de Delta Electronics DRASimuCAD. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Delta Electronics DRASimuCAD. Se requiere la interacción del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. La falla específica existe en el análisis de archivos STP. El problema es el resultado de la falta de una validación adecuada de los datos proporcionados por el usuario, lo que puede generar una condición de confusión de tipos. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. Era ZDI-CAN-22450."
    }
  ],
  "lastModified": "2026-06-17T07:00:36.387",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:deltaww:drasimucad:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "846ADC9F-279B-4430-BCB5-339E33A63E4A",
              "versionEndIncluding": "1.02.00.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com"
}