« Volver al listado

CVE-2024-12399

Estado: AplazadaMedia (6.1)—

CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-12399",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-12399",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-17T13:19:08.787250Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 5.5,
        "exploitabilityScore": 1.6
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.1,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "PASSIVE",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "LOW",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "Pro-face GP-Pro EX",
          "versions": [
            {
              "status": "affected",
              "version": "all version",
              "lessThan": "v5.00.100",
              "versionType": "version"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Pro-face Remote HMI",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "lessThan": "v1.70.000",
              "versionType": "version"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-01-17T10:15:06.697",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-014-02.pdf",
      "source": "cybersecurity@se.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-924"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
    },
    {
      "lang": "es",
      "value": "CWE-924: Existe una vulnerabilidad de aplicación inadecuada de la integridad del mensaje durante la transmisión en un canal de comunicación que podría causar una pérdida parcial de confidencialidad, pérdida de integridad y disponibilidad de la HMI cuando el atacante realiza un ataque man in the middle interceptando la comunicación."
    }
  ],
  "lastModified": "2026-06-17T06:59:39.077",
  "sourceIdentifier": "cybersecurity@se.com"
}