CVE-2024-1228

Status: ModifiedCritical (9.3)—
Severity9.3Critical · CVSS 4.0
Exploitation probability0.41 %higher than 34% of CVEs
Active exploitationNonot in the CISA catalog
Public exploitNot knownno public code found

Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.

This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).

CVSS

Base score
9.3
Version
4.0
Vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red

Exploitation probability (EPSS)

Probability of exploitation in the next 30 days
0.41 %
Percentile among all scored CVEs
34
Score date
10/21/2026

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Show 6 references

Raw JSON (NVD)

Show
{
  "id": "CVE-2024-1228",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-1228",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-06-10T13:42:43.489051Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cvd@cert.pl",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "USER",
          "baseScore": 9.3,
          "Automatable": "YES",
          "attackVector": "LOCAL",
          "baseSeverity": "CRITICAL",
          "valueDensity": "CONCENTRATED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:C/RE:M/U:Red",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "RED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "MODERATE",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cvd@cert.pl",
      "affectedData": [
        {
          "vendor": "EuroSoft Sp. z o. o.",
          "product": "Eurosoft Przychodnia",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "20240417.001",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:eurosoftsp.zo.o:eurosoft_przychodina:20240417.001:*:*:*:*:*:*:*"
          ],
          "vendor": "eurosoftsp.zo.o",
          "product": "eurosoft_przychodina",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "20240417.001",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-06-10T12:15:09.430",
  "references": [
    {
      "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia",
      "tags": [
        "Product"
      ],
      "source": "cvd@cert.pl"
    },
    {
      "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.eurosoft.com.pl/eurosoft-przychodnia",
      "tags": [
        "Product"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cvd@cert.pl",
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations.\n\nThis issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed)."
    },
    {
      "lang": "es",
      "value": "El uso de una contraseña codificada para la base de datos de los pacientes permite a un atacante recuperar datos confidenciales almacenados en la base de datos. La contraseña es la misma en todas las instalaciones de Eurosoft Przychodnia. Este problema afecta al software Eurosoft Przychodnia antes de la versión 20240417.001 (a partir de esa versión se soluciona la vulnerabilidad)."
    }
  ],
  "lastModified": "2026-06-17T07:03:45.677",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:eurosoft:przychodnia:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0EF7775C-026C-4F8E-8C72-0ECECF0AB425",
              "versionEndExcluding": "20240417.001"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cvd@cert.pl"
}