CVE-2024-11628
In Progress® Telerik® Kendo UI for Vue versions v2.4.0 through v6.0.1, an attacker can introduce or modify properties within the global prototype chain which can result in denial of service or command injection.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.69%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access75 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 % - Impacto secundario
T1499.004Application or System Exploitationimpact70 %
Vector AV:N sin UI permite explotación remota de aplicación web (Kendo UI). La descripción menciona inyección de comandos (T1059) y denegación de servicio (T1499) mediante manipulación del prototipo global.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-1321
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-11628",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-11628",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-02-12T19:06:14.995889Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security@progress.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "LOW",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 0.7
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "security@progress.com",
"affectedData": [
{
"vendor": "Progress Software",
"product": "Progress® Telerik® Kendo UI for Vue",
"versions": [
{
"status": "affected",
"version": "2.4.0",
"lessThan": "6.1.0",
"versionType": "custom"
}
],
"packageName": "@progress//kendo-vue-common",
"collectionURL": "https://registry.npmjs.org",
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-02-12T17:15:22.067",
"references": [
{
"url": "https://www.telerik.com/kendo-vue-ui/components/knowledge-base/kb-security-protoype-pollution-2024-11628",
"tags": [
"Vendor Advisory"
],
"source": "security@progress.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "security@progress.com",
"description": [
{
"lang": "en",
"value": "CWE-1321"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Progress® Telerik® Kendo UI for Vue versions v2.4.0 through v6.0.1, an attacker can introduce or modify properties within the global prototype chain which can result in denial of service or command injection."
},
{
"lang": "es",
"value": "En Progress® Telerik® Kendo UI para Vue versiones v2.4.0 a v6.0.1, un atacante puede introducir o modificar propiedades dentro de la cadena de prototipos global, lo que puede resultar en una denegación de servicio o inyección de comandos."
}
],
"lastModified": "2026-06-17T06:58:06.313",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:progress:kendo_ui_for_vue:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CE56334D-DFF3-4969-87F3-276E91DF5A70",
"versionEndExcluding": "6.1.0",
"versionStartIncluding": "2.4.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@progress.com"
}