CVE-2024-11598
Under specific circumstances, insecure permissions in Ivanti Application Control before version 2024.3 HF1, 2024.1 HF2, or 2023.3 HF3 allows a local authenticated attacker to achieve local privilege escalation.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 10
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation85 % - Impacto principal
T1548.004Elevated Execution with Promptprivilege escalation80 % - Impacto secundario
T1222File and Directory Permissions Modificationdefense impairment75 %
AV:L + PR:L sin interacción del usuario indica escalada local de privilegios. CWE-276 (insecure permissions) confirma T1548.004. El atacante obtiene acceso con permisos elevados explotando la configuración de permisos insegura del producto.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-276
- CWE-276
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-11598",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-11598",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-12-18T00:00:00+00:00"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
"affectedData": [
{
"vendor": "Ivanti",
"product": "Application Control",
"versions": [
{
"status": "unaffected",
"version": "2024.3 HF1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2024.1 HF2",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2023.3 HF3",
"versionType": "custom"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2024-12-11T17:15:14.453",
"references": [
{
"url": "https://forums.ivanti.com/s/article/December-2024-Security-Advisory-Ivanti-Application-Control-CVE-2024-11598",
"tags": [
"Vendor Advisory"
],
"source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Under specific circumstances, insecure permissions in Ivanti Application Control before version 2024.3 HF1, 2024.1 HF2, or 2023.3 HF3 allows a local authenticated attacker to achieve local privilege escalation."
},
{
"lang": "es",
"value": "En circunstancias específicas, los permisos inseguros en Ivanti Application Control anteriores a la versión 2024.3 HF1, 2024.1 HF2 o 2023.3 HF3 permiten que un atacante autenticado local logre una escalada de privilegios locales."
}
],
"lastModified": "2026-06-17T06:58:02.390",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ivanti:application_control:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA57F84F-C75C-4742-BA72-C948D231FD50",
"versionEndIncluding": "2023.3"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2023.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3824F2AD-3D52-4874-9468-76CD8ABA051B"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2023.3:hf1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7B4A0566-0FB2-4AFC-A202-B6C1C09F4616"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2023.3:hf2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4FEA9599-9981-4640-A02B-64BC2D826597"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2024.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DD963203-04A4-4C8B-B900-3E0B8259E64C"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2024.1:hf1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2CC58F0C-035A-45E0-9523-056AF0C98086"
},
{
"criteria": "cpe:2.3:a:ivanti:application_control:2024.3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "64320F86-5E36-4110-83F8-037C67A584C1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75"
}