CVE-2024-11499
Estado: AplazadaMedia (6.9)—
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.
The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:A/V:X/RE:X/U:X
- Puntuación base: 6.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 14
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-476
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-11499",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-11499",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-25T13:11:51.667437Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 1.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "AUTOMATIC",
"baseScore": 6.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:A/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@hitachienergy.com",
"affectedData": [
{
"vendor": "Hitachi Energy",
"product": "RTU500",
"versions": [
{
"status": "affected",
"version": "13.4.1",
"versionType": "custom",
"lessThanOrEqual": "13.4.4"
},
{
"status": "affected",
"version": "13.5.1",
"versionType": "custom",
"lessThanOrEqual": "13.5.3"
},
{
"status": "affected",
"version": "13.5.3",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.6.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "13.7.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.5.4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.6.2",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "13.7.6",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-03-25T13:15:39.890",
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207&languageCode=en&Preview=true",
"source": "cybersecurity@hitachienergy.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@hitachienergy.com",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections.\n\nThe affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad en la funcionalidad de la estación controlada RTU500 IEC 60870-4-104 que permite a un atacante autenticado y autorizado reiniciar la CMU. Esta vulnerabilidad puede activarse si los certificados se actualizan mientras se utilizan en conexiones activas. La CMU afectada se recuperará automáticamente si un atacante explota esta vulnerabilidad."
}
],
"lastModified": "2026-06-17T06:57:51.280",
"sourceIdentifier": "cybersecurity@hitachienergy.com"
}