CVE-2024-10035
Improper Control of Generation of Code ('Code Injection'), Improper Neutralization of Special Elements used in a Command ('Command Injection'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in BG-TEK Informatics Security Technologies CoslatV3 allows Command Injection, Privilege Escalation.
This issue affects CoslatV3: through 3.1069.
NOTE: The vendor was contacted and it was learned that the product is not supported.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.85%
- Percentil entre todas las CVEs puntuadas: 57
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation90 % - Impacto principal
T1059Command and Scripting Interpreterexecution95 %
Vector AV:L/PR:L indica acceso local con privilegios de usuario. CWE-78 (OS Command Injection) y descripción explícita de 'Command Injection' confirman ejecución de comandos. La escalada de privilegios (PR:L→VC:H) se logra mediante inyección de comandos del SO.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-77, CWE-78, CWE-94
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-10035",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "iletisim@usom.gov.tr"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-10035",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-04T15:07:32.669713Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.2,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "iletisim@usom.gov.tr",
"affectedData": [
{
"vendor": "BG-TEK Informatics Security Technologies",
"product": "CoslatV3",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "3.1069"
}
],
"defaultStatus": "affected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:bg-tek:coslatv3_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "bg-tek",
"product": "coslatv3_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "3.1069"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2024-11-04T12:16:08.880",
"references": [
{
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-1814",
"source": "iletisim@usom.gov.tr"
},
{
"url": "https://www.usom.gov.tr/bildirim/tr-24-1814",
"tags": [
"Third Party Advisory"
],
"source": "iletisim@usom.gov.tr"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"description": [
{
"lang": "en",
"value": "CWE-77"
},
{
"lang": "en",
"value": "CWE-78"
},
{
"lang": "en",
"value": "CWE-94"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Control of Generation of Code ('Code Injection'), Improper Neutralization of Special Elements used in a Command ('Command Injection'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in BG-TEK Informatics Security Technologies CoslatV3 allows Command Injection, Privilege Escalation.\n\nThis issue affects CoslatV3: through 3.1069.\n\n\n\n\n\nNOTE: The vendor was contacted and it was learned that the product is not supported."
},
{
"lang": "es",
"value": "La vulnerabilidad de control inadecuado de la generación de código ('inyección de código') en CoslatV3 de BG-TEK Informatics Security Technologies permite la inyección de comandos. Este problema afecta a CoslatV3: hasta 3.1069. NOTA: Se contactó al proveedor y se supo que el producto no cuenta con soporte."
}
],
"lastModified": "2026-06-17T06:54:48.657",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:bg-tek:coslat:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "48F69F76-631D-4326-A504-415B7C8B6EC8",
"versionEndIncluding": "3.1069",
"versionStartIncluding": "3.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "iletisim@usom.gov.tr"
}