CVE-2024-0833
Estado: ModificadaAlta (7.8)—
In Telerik Test Studio versions prior to
v2023.3.1330, a privilege elevation vulnerability has been identified in the applications installer component. In an environment where an existing Telerik Test Studio install is present, a lower privileged user has the ability to manipulate the installation package to elevate their privileges on the underlying operating system.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-269
- NVD-CWE-noinfo
- CWE-276
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-0833",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-0833",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-04-01T17:23:21.877051Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security@progress.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "security@progress.com",
"affectedData": [
{
"vendor": "Progress Software",
"modules": [
"Telerik Test Studio Installer"
],
"product": "Telerik Test Studio",
"versions": [
{
"status": "affected",
"version": "2011.0",
"lessThan": "v2023.3.1330",
"versionType": "semver"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2024-01-31T16:15:46.600",
"references": [
{
"url": "https://docs.telerik.com/teststudio/knowledge-base/product-notices-kb/legacy-installer-vulnerability",
"tags": [
"Vendor Advisory"
],
"source": "security@progress.com"
},
{
"url": "https://www.telerik.com/teststudio",
"tags": [
"Product"
],
"source": "security@progress.com"
},
{
"url": "https://docs.telerik.com/teststudio/knowledge-base/product-notices-kb/legacy-installer-vulnerability",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.telerik.com/teststudio",
"tags": [
"Product"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "security@progress.com",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Telerik Test Studio versions prior to \n\nv2023.3.1330, a privilege elevation vulnerability has been identified in the applications installer component. In an environment where an existing Telerik Test Studio install is present, a lower privileged user has the ability to manipulate the installation package to elevate their privileges on the underlying operating system."
},
{
"lang": "es",
"value": "En las versiones de Telerik Test Studio anteriores a la v2023.3.1330, se identificó una vulnerabilidad de elevación de privilegios en el componente del instalador de aplicaciones. En un entorno donde existe una instalación de Telerik Test Studio, un usuario con privilegios bajos tiene la capacidad de manipular el paquete de instalación para elevar sus privilegios en el sistema operativo subyacente."
}
],
"lastModified": "2026-06-17T06:54:24.050",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:progress:telerik_test_studio:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "57245635-375B-4EEB-9881-E9B20FD2F37F",
"versionEndExcluding": "2023.3.1330"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security@progress.com"
}