« Volver al listado

CVE-2023-7163

Estado: ModificadaCrítica (9.8)—

A security issue exists in D-Link D-View 8 v2.0.2.89 and prior that could allow an attacker to manipulate the probe inventory of the D-View service. This could result in the disclosure of information from other probes, denial of service conditions due to the probe inventory becoming full, or the execution of tasks on other probes.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-7163",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "vulnreport@tenable.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 10,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "vulnreport@tenable.com",
      "affectedData": [
        {
          "vendor": "D-Link",
          "product": "D-View 8",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "2.0.2.89"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-12-28T16:16:02.730",
  "references": [
    {
      "url": "https://tenable.com/security/research/tra-2023-43",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "vulnreport@tenable.com"
    },
    {
      "url": "https://tenable.com/security/research/tra-2023-43",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "vulnreport@tenable.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A security issue exists in D-Link D-View 8 v2.0.2.89 and prior that could allow an attacker to manipulate the probe inventory of the D-View service. This could result in the disclosure of information from other probes, denial of service conditions due to the probe inventory becoming full, or the execution of tasks on other probes.\n\n"
    },
    {
      "lang": "es",
      "value": "Existe un problema de seguridad en D-Link D-View 8 v2.0.2.89 y anteriores que podría permitir a un atacante manipular el inventario de sonda del servicio D-View. Esto podría dar como resultado la divulgación de información de otras sondas, la denegación de condiciones de servicio debido a que el inventario de la sonda se llena o la ejecución de tareas en otras sondas."
    }
  ],
  "lastModified": "2026-06-17T06:52:12.880",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dlink:d-view_8:2.0.2.89:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A91C8832-E4F4-47AD-986A-2C63EEBF9B6C"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "vulnreport@tenable.com"
}