Estado: ModificadaMedia (4.3)—

A vulnerability was found in Uniway UW-302VP 2.0. It has been rated as problematic. This issue affects some unknown processing of the file /boaform/wlan_basic_set.cgi of the component Admin Web Interface. The manipulation of the argument wlanssid/password leads to cross-site request forgery. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-248939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-7092",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Uniway",
          "modules": [
            "Admin Web Interface"
          ],
          "product": "UW-302VP",
          "versions": [
            {
              "status": "affected",
              "version": "2.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-12-24T23:15:08.290",
  "references": [
    {
      "url": "https://drive.google.com/file/d/15Wr3EL4cpAS_H_Vp7TuIftssxAuzb4SL/view",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.248939",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.248939",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://drive.google.com/file/d/15Wr3EL4cpAS_H_Vp7TuIftssxAuzb4SL/view",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?ctiid.248939",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.248939",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Uniway UW-302VP 2.0. It has been rated as problematic. This issue affects some unknown processing of the file /boaform/wlan_basic_set.cgi of the component Admin Web Interface. The manipulation of the argument wlanssid/password leads to cross-site request forgery. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-248939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se encontró una vulnerabilidad en Uniway UW-302VP 2.0. Ha sido calificada como problemática. Este problema afecta a un procesamiento desconocido del archivo /boaform/wlan_basic_set.cgi del componente Admin Web Interface. La manipulación del argumento wlanssid/password conduce a cross-site request forgery. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-248939. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna forma."
    }
  ],
  "lastModified": "2026-06-17T06:52:02.787",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:uniwayinfo:uw-302vp_firmware:2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2537948A-9148-4BFB-B8C4-993F53844BF2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:uniwayinfo:uw-302vp:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BEB01B31-0127-430F-8683-4A90FE8BA490"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}