CVE-2023-7017
Status: DeferredCritical (9.8)—
Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 9.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.29%
- Percentile among all scored CVEs: 20
- Score date: 10/8/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
References
Raw JSON (NVD)
Show
{
"id": "CVE-2023-7017",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-7017",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-03-15T19:25:24.356996Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "Sciener",
"product": "Kontrol Lux",
"versions": [
{
"status": "affected",
"version": "6.5.x",
"versionType": "custom",
"lessThanOrEqual": "6.5.07"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:sciener:kontrol_lux_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "sciener",
"product": "kontrol_lux_firmware",
"versions": [
{
"status": "affected",
"version": "6.5.x",
"versionType": "custom",
"lessThanOrEqual": "6.5.07"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-03-15T17:15:07.857",
"references": [
{
"url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/",
"source": "cret@cert.org"
},
{
"url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.kb.cert.org/vuls/id/949046",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"descriptions": [
{
"lang": "en",
"value": "Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device."
},
{
"lang": "es",
"value": "El mecanismo de actualización de firmware de las cerraduras Sciener no autentica ni valida las actualizaciones de firmware si se pasan a la cerradura a través del servicio Bluetooth Low Energy. Se puede enviar una solicitud de desafío a la cerradura con un comando para prepararse para una actualización, en lugar de una solicitud de desbloqueo, lo que permite a un atacante comprometer el dispositivo."
}
],
"lastModified": "2026-06-17T06:51:52.813",
"sourceIdentifier": "cret@cert.org"
}