CVE-2023-7009
Status: DeferredHigh (8.2)—
Some Sciener-based locks support plaintext message processing over Bluetooth Low Energy, allowing unencrypted malicious commands to be passed to the lock. These malicious commands, less then 16 bytes in length, will be processed by the lock as if they were encrypted communications. This can be further exploited by an attacker to compromise the lock's integrity.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N
- Base score: 8.2
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.25%
- Percentile among all scored CVEs: 15
- Score date: 10/8/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
References
Raw JSON (NVD)
Show
{
"id": "CVE-2023-7009",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-7009",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-08-26T15:09:45.609770Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 4.2,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "Sciener",
"product": "Kontrol Lux",
"versions": [
{
"status": "affected",
"version": "6.5.x",
"versionType": "custom",
"lessThanOrEqual": "6.5.07"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:sciener:kontrol_lux_firmware:6.5:*:*:*:*:*:*:*"
],
"vendor": "sciener",
"product": "kontrol_lux_firmware",
"versions": [
{
"status": "affected",
"version": "6.5",
"versionType": "custom",
"lessThanOrEqual": "6.5.07"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-03-15T17:15:07.810",
"references": [
{
"url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/",
"source": "cret@cert.org"
},
{
"url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.kb.cert.org/vuls/id/949046",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"descriptions": [
{
"lang": "en",
"value": "Some Sciener-based locks support plaintext message processing over Bluetooth Low Energy, allowing unencrypted malicious commands to be passed to the lock. These malicious commands, less then 16 bytes in length, will be processed by the lock as if they were encrypted communications. This can be further exploited by an attacker to compromise the lock's integrity."
},
{
"lang": "es",
"value": "Algunas cerraduras basadas en Sciener admiten el procesamiento de mensajes de texto plano a través de Bluetooth Low Energy, lo que permite pasar comandos maliciosos sin cifrar a la cerradura. Estos comandos maliciosos, de menos de 16 bytes de longitud, serán procesados por la cerradura como si fueran comunicaciones cifradas. Un atacante puede aprovechar aún más esto para comprometer la integridad del bloqueo."
}
],
"lastModified": "2026-06-17T06:51:51.670",
"sourceIdentifier": "cret@cert.org"
}