CVE-2023-52952
A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (All versions >= V11.5.1 < V11.6.2). The Kiosk Mode of the affected devices contains a restricted desktop environment escape vulnerability. This could allow an unauthenticated local attacker to escape the restricted environment and gain access to the underlying operating system.
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Base score: 9.3
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.17%
- Percentile among all scored CVEs: 6
- Score date: 10/7/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Primary impact
T1548Abuse Elevation Control Mechanismprivilege escalation85 %
AV:L sin UI:R indica escalada local. Escape de Kiosk Mode en dispositivo HiMed permite acceso sin autenticación al SO subyacente, ganando privilegios administrativos (VC:H confirma compromiso de confidencialidad/integridad del sistema).
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (4)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-424
References
Raw JSON (NVD)
Show
{
"id": "CVE-2023-52952",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-52952",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-10-08T14:06:56.023306Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.5,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 5.3,
"exploitabilityScore": 2.5
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "HiMed Cockpit 12 pro",
"versions": [
{
"status": "affected",
"version": "V11.5.1",
"lessThan": "V11.6.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "HiMed Cockpit 14 pro+",
"versions": [
{
"status": "affected",
"version": "V11.5.1",
"lessThan": "V11.6.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "HiMed Cockpit 18 pro",
"versions": [
{
"status": "affected",
"version": "V11.5.1",
"lessThan": "V11.6.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "HiMed Cockpit 18 pro+",
"versions": [
{
"status": "affected",
"version": "V11.5.1",
"lessThan": "V11.6.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-10-08T09:15:10.097",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-540493.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-424"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (All versions >= V11.5.1 < V11.6.2). The Kiosk Mode of the affected devices contains a restricted desktop environment escape vulnerability. This could allow an unauthenticated local attacker to escape the restricted environment and gain access to the underlying operating system."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en HiMed Cockpit 12 pro (J31032-K2017-H259) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (todas las versiones >= V11.5.1 < V11.6.2). El modo quiosco de los dispositivos afectados contiene una vulnerabilidad de escape del entorno de escritorio restringido. Esto podría permitir que un atacante local no autenticado escape del entorno restringido y obtenga acceso al sistema operativo subyacente."
}
],
"lastModified": "2026-06-17T06:44:00.583",
"sourceIdentifier": "productcert@siemens.com"
}