« Volver al listado

CVE-2023-50000

Estado: ModificadaCrítica (9.8)—

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-50000",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-12-07T17:15:07.420",
  "references": [
    {
      "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_resetMesh/w30e_resetMesh.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_resetMesh/w30e_resetMesh.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode."
    },
    {
      "lang": "es",
      "value": "Se descubrió que Tenda W30E V16.01.0.12(4843) contenía un desbordamiento de pila a través de la función formResetMeshNode."
    }
  ],
  "lastModified": "2026-06-17T06:39:04.170",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6B656886-847F-4F68-8DD3-B91B19FCFC28"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "02FBE634-0D3F-4439-B4A6-F427C82967C7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}