CVE-2023-49722
Estado: ModificadaMedia (6.5)—
Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.44%
- Percentil entre todas las CVEs puntuadas: 36
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-1125
- NVD-CWE-Other
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-49722",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-49722",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-01-09T13:58:04.983004Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 5.5,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@bosch.com",
"affectedData": [
{
"vendor": "Bosch",
"product": "BCC101",
"versions": [
{
"status": "affected",
"version": "4.13.20",
"lessThan": "v4.13.33",
"versionType": "custom"
}
]
},
{
"vendor": "Bosch",
"product": "BCC102",
"versions": [
{
"status": "affected",
"version": "4.13.20",
"lessThan": "v4.13.33",
"versionType": "custom"
}
]
},
{
"vendor": "Bosch",
"product": "BCC50",
"versions": [
{
"status": "affected",
"version": "4.13.20",
"lessThan": "v4.13.33",
"versionType": "custom"
}
]
}
]
}
],
"published": "2024-01-09T10:15:20.720",
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html",
"tags": [
"Vendor Advisory"
],
"source": "psirt@bosch.com"
},
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-473852.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@bosch.com",
"description": [
{
"lang": "en",
"value": "CWE-1125"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Network port 8899 open in WiFi firmware of BCC101/BCC102/BCC50 products, that allows an attacker to connect to the device via same WiFi network."
},
{
"lang": "es",
"value": "El puerto de red 8899 está abierto en el firmware WiFi de los productos BCC101/BCC102/BCC50, que permite a un atacante conectarse al dispositivo a través de la misma red WiFi."
}
],
"lastModified": "2026-06-17T06:36:21.200",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:bcc101_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DBDA6413-E7A3-4566-9F04-4B7AB937EB4C",
"versionEndExcluding": "4.13.33",
"versionStartIncluding": "4.13.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:bcc101:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F914736C-5826-4A7A-A7E1-97553D324F6B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:bcc102_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "790AE7CC-DB71-4F39-ADB2-665FEF22AEB5",
"versionEndExcluding": "4.13.33",
"versionStartIncluding": "4.13.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:bcc102:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1B1DB812-82C4-415E-A79E-A3464C3FAA03"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:bcc50_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0CEEF136-27E9-49F6-A6CB-DC6AE02964A7",
"versionEndExcluding": "4.13.33",
"versionStartIncluding": "4.13.20"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:bcc50:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E3DCAF6D-ED0D-4242-870B-13C63FC69082"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@bosch.com"
}