« Volver al listado

CVE-2023-48428

Estado: ModificadaAlta (7.2)—

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-48428",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-48428",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-01-06T05:01:18.437822Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC INS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V1.0 SP2 Update 2"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-12-12T12:15:14.873",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones &lt; V1.0 SP2 Update 2). El mecanismo de configuración de radio de los productos afectados no verifica correctamente los certificados cargados. Un administrador malintencionado podría cargar un certificado manipulado, lo que provocaría una condición de denegación de servicio o podría emitir comandos a nivel del sistema."
    }
  ],
  "lastModified": "2026-06-17T06:34:14.353",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5",
              "versionEndExcluding": "1.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}