CVE-2023-46916
Status: ModifiedMedium (4.3)—
Maxima Max Pro Power 1.0 486A devices allow BLE traffic replay. An attacker can use GATT characteristic handle 0x0012 to perform potentially disruptive actions such as starting a Heart Rate monitor.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
- Base score: 4.3
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.51%
- Percentile among all scored CVEs: 42
- Score date: 10/8/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- NVD-CWE-noinfo
References
Raw JSON (NVD)
Show
{
"id": "CVE-2023-46916",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-46916",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-10-10T17:33:06.588140Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2023-12-07T06:15:54.803",
"references": [
{
"url": "http://packetstormsecurity.com/files/175660",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.maximawatches.com/products/max-pro-power",
"tags": [
"Product"
],
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/175660",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.maximawatches.com/products/max-pro-power",
"tags": [
"Product"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Maxima Max Pro Power 1.0 486A devices allow BLE traffic replay. An attacker can use GATT characteristic handle 0x0012 to perform potentially disruptive actions such as starting a Heart Rate monitor."
},
{
"lang": "es",
"value": "Los dispositivos Maxima Max Pro Power 1.0 486A permiten la reproducción del tráfico BLE. Un atacante puede utilizar el identificador de característica GATT 0x0012 para realizar acciones potencialmente disruptivas, como iniciar un monitor de frecuencia cardíaca."
}
],
"lastModified": "2026-06-17T06:31:49.720",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:maximawatches:maxima_max_pro_power_firmware:1.0_486a:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "715096FF-8DF3-4877-B4AE-073FA4F0D86A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:maximawatches:maxima_max_pro_power:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "93F050F9-344A-4F7D-84D7-7964DF1886EF"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}