« Volver al listado

CVE-2023-4292

Estado: ModificadaMedia (5.3)—

Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-4292",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-4292",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-24T18:18:17.024082Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "info@cert.vde.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "info@cert.vde.com",
      "affectedData": [
        {
          "vendor": "Frauscher",
          "product": "FDS101 for FAdC/FAdCi",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "1.4.24"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-09-21T07:15:19.817",
  "references": [
    {
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-038",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "info@cert.vde.com"
    },
    {
      "url": "https://https://cert.vde.com/en/advisories/VDE-2023-038",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "info@cert.vde.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "Frauscher Sensortechnik GmbH FDS101 para FAdC/FAdCi v1.4.24 y todas las versiones anteriores son vulnerables a una vulnerabilidad de inyección SQL a través de parámetros manipulados de la interfaz web sin autenticación. La base de datos contiene información de registro limitada y no crítica."
    }
  ],
  "lastModified": "2026-06-17T06:37:29.343",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadc:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8C27C13A-FDC8-4E2C-A4E0-324A29040DC5",
              "versionEndIncluding": "1.4.24"
            },
            {
              "criteria": "cpe:2.3:a:frauscher:frauscher_diagnostic_system_101:*:*:*:*:*:fadci:*:*",
              "vulnerable": true,
              "matchCriteriaId": "65E1CCBA-51DB-439D-951F-1EC97EB9E58D",
              "versionEndIncluding": "1.4.24"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "info@cert.vde.com"
}