CVE-2023-40597
Estado: ModificadaAlta (8.8)—
In Splunk Enterprise versions lower than 8.2.12, 9.0.6, and 9.1.1, an attacker can exploit an absolute path traversal to execute arbitrary code that is located on a separate disk.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-36
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-40597",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-40597",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-01T13:44:33.147826Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "prodsec@splunk.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 2
}
]
},
"affected": [
{
"source": "prodsec@splunk.com",
"affectedData": [
{
"vendor": "Splunk",
"product": "Splunk Enterprise",
"versions": [
{
"status": "affected",
"version": "8.2",
"lessThan": "8.2.12",
"versionType": "custom"
},
{
"status": "affected",
"version": "9.0",
"lessThan": "9.0.6",
"versionType": "custom"
},
{
"status": "affected",
"version": "9.1",
"lessThan": "9.1.1",
"versionType": "custom"
}
]
},
{
"vendor": "Splunk",
"product": "Splunk Cloud",
"versions": [
{
"status": "affected",
"version": "-",
"lessThan": "9.0.2305.200",
"versionType": "custom"
}
]
}
]
}
],
"published": "2023-08-30T17:15:10.180",
"references": [
{
"url": "https://advisory.splunk.com/advisories/SVD-2023-0806",
"tags": [
"Vendor Advisory"
],
"source": "prodsec@splunk.com"
},
{
"url": "https://research.splunk.com/application/356bd3fe-f59b-4f64-baa1-51495411b7ad/",
"tags": [
"Vendor Advisory"
],
"source": "prodsec@splunk.com"
},
{
"url": "https://advisory.splunk.com/advisories/SVD-2023-0806",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://research.splunk.com/application/356bd3fe-f59b-4f64-baa1-51495411b7ad/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "prodsec@splunk.com",
"description": [
{
"lang": "en",
"value": "CWE-36"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Splunk Enterprise versions lower than 8.2.12, 9.0.6, and 9.1.1, an attacker can exploit an absolute path traversal to execute arbitrary code that is located on a separate disk."
},
{
"lang": "es",
"value": "En las versiones de Splunk Enterprise inferiores a 8.2.12, 9.0.6 y 9.1.1, un atacante puede explotar un salto de ruta absoluto para ejecutar código arbitrario que se encuentra en un disco separado."
}
],
"lastModified": "2026-06-17T06:18:38.617",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*",
"vulnerable": true,
"matchCriteriaId": "21F6F824-393F-424F-85DF-CD3FCB40452F",
"versionEndExcluding": "8.2.12",
"versionStartIncluding": "8.2.0"
},
{
"criteria": "cpe:2.3:a:splunk:splunk:*:*:*:*:enterprise:*:*:*",
"vulnerable": true,
"matchCriteriaId": "74A23E71-6A34-48A5-8087-B626BED870E0",
"versionEndExcluding": "9.0.6",
"versionStartIncluding": "9.0.0"
},
{
"criteria": "cpe:2.3:a:splunk:splunk:9.1.0:*:*:*:enterprise:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4F2BC82-AD4C-4D80-8200-C2371E7C04F1"
},
{
"criteria": "cpe:2.3:a:splunk:splunk_cloud_platform:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A2A0FF7F-1171-42D4-A27B-689541F4BC32",
"versionEndIncluding": "9.0.2305.100"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "prodsec@splunk.com"
}