CVE-2023-38940
Estado: ModificadaCrítica (9.8)—
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.84%
- Percentil entre todas las CVEs puntuadas: 56
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-38940",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-38940",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-10-11T14:16:25.895234Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "f1203",
"versions": [
{
"status": "affected",
"version": "V2.0.1.6"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "fh1203",
"versions": [
{
"status": "affected",
"version": "V2.0.1.6"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "fh1205",
"versions": [
{
"status": "affected",
"version": "V2.0.0.7(775)"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-08-07T19:15:11.610",
"references": [
{
"url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function."
}
],
"lastModified": "2026-06-17T06:11:21.793",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}