« Volver al listado

CVE-2023-38906

Estado: ModificadaMedia (6.5)—

An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-38906",
  "cveTags": [],
  "metrics": {
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-08-22T00:15:07.920",
  "references": [
    {
      "url": "https://arxiv.org/abs/2308.09019",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf",
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=&t=1",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://arxiv.org/abs/2308.09019",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.dmi.unict.it/giamp/smartbulbscanbehackedtohackintoyourhousehold/",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.scitepress.org/Papers/2023/120929/120929.pdf",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.scitepress.org/PublicationsDetail.aspx?ID=X/auBv7JrSo=&t=1",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue in TPLink Smart Bulb Tapo series L530 1.1.9, L510E 1.0.8, L630 1.0.3, P100 1.4.9, Smart Camera Tapo series C200 1.1.18, and Tapo Application 2.8.14 allows a remote attacker to obtain sensitive information via the authentication code for the UDP message."
    },
    {
      "lang": "es",
      "value": "Un problema en la bombilla inteligente TP Link Tapo serie L530 v.1.0.0 y la aplicación Tapo v.2.8.14 permite a un atacante remoto obtener información confidencial a través del código de autenticación para el mensaje UDP."
    }
  ],
  "lastModified": "2026-06-17T06:11:17.717",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:tp-link:tapo:2.8.14:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D392C8A7-8A3F-490A-90B5-F7D7BFDC7F72"
            },
            {
              "criteria": "cpe:2.3:o:tp-link:tapo_l530e_firmware:1.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0427C4E5-322A-40F0-AA88-2FF57A32885F"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tp-link:tapo_l530e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "49091A2E-84FF-4A44-87EE-2BA8C366BE51"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}