« Volver al listado

CVE-2023-37194

Estado: ModificadaMedia (6.7)—

A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (5)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-37194",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-37194",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-19T14:23:50.733459Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.7,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1604",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1616",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1623",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1626",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC CP 1628",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "simatic_cp_1604_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "simatic_cp_1616_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "simatic_cp_1623_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "simatic_cp_1626_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "simatic_cp_1628_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-10-10T11:15:11.903",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en: \nSIMATIC CP 1604 (Todas las versiones), \nSIMATIC CP 1616 (Todas las versiones), \nSIMATIC CP 1623 (Todas las versiones), \nSIMATIC CP 1626 (Todas las versiones), \nSIMATIC CP 1628 (Todas las versiones). \nLa memoria del kernel de los dispositivos afectados está expuesta al modo de usuario a través del acceso directo a la memoria (DMA), lo que podría permitir a un atacante local con privilegios administrativos ejecutar código arbitrario en el host system sin ninguna restricción."
    }
  ],
  "lastModified": "2026-06-17T06:07:41.960",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "152B002C-C7B0-4891-9D78-0E2464D33B92"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4D249133-0B8A-4587-B453-44852E3EAFC6"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "23579942-1BD9-4D73-9AD7-0FA68E5FDFDA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1B56820D-3842-4810-A9A9-F7F051C81374"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3B55E584-06BA-4E1C-93B0-004B506FCBF3"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A397C5DD-6495-463D-8EEF-9F1325A0B6CF"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "597593D3-BCFD-40DF-A83C-18F9D134863B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}