« Volver al listado

CVE-2023-36635

Estado: ModificadaMedia (4.3)—

An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2 7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-36635",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-36635",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-26T14:00:27.488932Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "psirt@fortinet.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "psirt@fortinet.com",
      "affectedData": [
        {
          "vendor": "Fortinet",
          "product": "FortiSwitchManager",
          "versions": [
            {
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver",
              "lessThanOrEqual": "7.2.2"
            },
            {
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver",
              "lessThanOrEqual": "7.0.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-09-07T13:15:08.433",
  "references": [
    {
      "url": "https://fortiguard.com/psirt/FG-IR-22-174",
      "tags": [
        "Not Applicable",
        "Vendor Advisory"
      ],
      "source": "psirt@fortinet.com"
    },
    {
      "url": "https://fortiguard.com/psirt/FG-IR-22-174",
      "tags": [
        "Not Applicable",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "psirt@fortinet.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API."
    },
    {
      "lang": "es",
      "value": "Un control de acceso incorrecto en Fortinet FortiSwitchManager, versiones 7.2.0 a 7.2.2 y versiones 7.0.0 a 7.0.1, puede permitir que un usuario remoto autenticado con permisos de solo lectura modifique la configuración de la interfaz a través de la API."
    }
  ],
  "lastModified": "2026-06-17T06:06:43.133",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5B4A6B0D-1614-443B-8EBA-A8FBC2E1A832"
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "331A1766-4EBA-4519-A8ED-E0DD68A187E9"
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2B73D78B-2270-45B7-854E-F985B8D88F3B"
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "469E9E1C-154C-41CB-AC83-FBE5E6FA83EB"
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "959248C7-DC92-4968-87F9-2A2CDF84F7BE"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "psirt@fortinet.com"
}