CVE-2023-34430
Estado: ModificadaAlta (7.8)—
Uncontrolled search path in some Intel Battery Life Diagnostic Tool software before version 2.2.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.20%
- Percentil entre todas las CVEs puntuadas: 9
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-427
- CWE-427
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-34430",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-34430",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-08-30T15:23:25.791037Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "secure@intel.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.7,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel Battery Life Diagnostic Tool software",
"versions": [
{
"status": "affected",
"version": "before version 2.2.1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-11-14T19:15:28.240",
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00843.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00843.html",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "secure@intel.com",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Uncontrolled search path in some Intel Battery Life Diagnostic Tool software before version 2.2.1 may allow an authenticated user to potentially enable escalation of privilege via local access."
},
{
"lang": "es",
"value": "La ruta de búsqueda no controlada en algunos software Intel Battery Life Diagnostic Tool anterior a la versión 2.2.1 puede permitir que un usuario autenticado potencialmente habilite la escalada de privilegios a través del acceso local."
}
],
"lastModified": "2026-06-17T06:03:37.917",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:intel:battery_life_diagnostic_tool:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD5E894A-220F-46C6-BF57-F2C1A5DADF3C",
"versionEndExcluding": "2.2.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}