CVE-2023-33919
Estado: ModificadaAlta (7.2)—
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 48%
- Percentil entre todas las CVEs puntuadas: 99
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-77
- CWE-77
Referencias
- http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html
- http://seclists.org/fulldisclosure/2023/Jul/14
- http://seclists.org/fulldisclosure/2024/Jul/4
- https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf
- http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html
- http://seclists.org/fulldisclosure/2023/Jul/14
- http://seclists.org/fulldisclosure/2024/Jul/4
- http://seclists.org/fulldisclosure/2025/Feb/19
- https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-33919",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-33919",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-07-05T20:17:08.721536Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "CP-8031 MASTER MODULE",
"versions": [
{
"status": "affected",
"version": "All versions < CPCI85 V05"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "CP-8050 MASTER MODULE",
"versions": [
{
"status": "affected",
"version": "All versions < CPCI85 V05"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "cp-8031_master_module",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "CVE-2022-33307",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"cpes": [
"cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "cp-8050_master_module",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "CVE-2022-33307",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-06-13T09:15:18.620",
"references": [
{
"url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html",
"source": "productcert@siemens.com"
},
{
"url": "http://seclists.org/fulldisclosure/2023/Jul/14",
"source": "productcert@siemens.com"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Jul/4",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2023/Jul/14",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2024/Jul/4",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Feb/19",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"lastModified": "2026-06-17T06:02:31.007",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "59D83EB4-A263-4070-A864-56EB7B120CE2",
"versionEndExcluding": "v05"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E84CEC33-3B34-42EF-A698-164AF0343316"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "59D83EB4-A263-4070-A864-56EB7B120CE2",
"versionEndExcluding": "v05"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E7686251-7011-46F9-9CEB-CC5DADCB5284"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}