CVE-2023-33806
Estado: AnalizadaAlta (7.8)—
Insecure default configurations in Hikvision Interactive Tablet DS-D5B86RB/B V2.3.0 build220119, allows attackers to execute arbitrary commands.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-77
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-33806",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-33806",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-07-31T15:38:11.740434Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:hikvision:ds-d5b86rb\\/b_firmware:2.3.0:*:*:*:*:*:*:*"
],
"vendor": "hikvision",
"product": "ds-d5b86rb\\/b_firmware",
"versions": [
{
"status": "affected",
"version": "2.3.0"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-15T23:15:06.837",
"references": [
{
"url": "https://gist.github.com/s4fv4n/5a6374cf1dcad85226566eaa325a710d",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://gist.github.com/s4fv4n/5a6374cf1dcad85226566eaa325a710d",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insecure default configurations in Hikvision Interactive Tablet DS-D5B86RB/B V2.3.0 build220119, allows attackers to execute arbitrary commands."
},
{
"lang": "es",
"value": "Las configuraciones predeterminadas inseguras en Hikvision Interactive Tablet DS-D5B86RB/B V2.3.0 build220119 permiten a los atacantes ejecutar comandos arbitrarios."
}
],
"lastModified": "2026-06-17T06:02:19.667",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-d5b86rb\\/b_firmware:2.3.0:build220119:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EC53A329-FDEA-4B06-9B3C-E2BB1224D58D"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-d5b86rb\\/b:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "661F153F-61BA-4461-B5D6-C922ACD710FD"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}