CVE-2023-31115
Estado: ModificadaAlta (7.5)—
An issue was discovered in the Shannon RCS component in Samsung Exynos Modem 5123 and 5300. Incorrect resource transfer between spheres can cause changes to the activation mode of RCS via a crafted application.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.49%
- Percentil entre todas las CVEs puntuadas: 40
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-669
- CWE-669
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-31115",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-31115",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-01-07T14:46:04.995440Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2023-06-07T21:15:13.407",
"references": [
{
"url": "https://semiconductor.samsung.com/support/quality-support/product-security-updates/",
"tags": [
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://semiconductor.samsung.com/support/quality-support/product-security-updates/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-669"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-669"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in the Shannon RCS component in Samsung Exynos Modem 5123 and 5300. Incorrect resource transfer between spheres can cause changes to the activation mode of RCS via a crafted application."
},
{
"lang": "es",
"value": "Se descubrió un problema en Shannon RCS component en Samsung Exynos Modem 5123 y 5300. La transferencia incorrecta de recursos entre esferas puede provocar cambios en el modo de activación de RCS a través de una aplicación manipulada específicamente para ello."
}
],
"lastModified": "2026-06-17T05:56:18.497",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:samsung:exynos_5123_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EFFB4DF2-B55C-45BD-9073-56299E19B6DE"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:samsung:exynos_5123:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A5954D95-E12B-487D-9744-361566788A2D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:samsung:exynos_5300_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6E2E6EE0-4271-43A3-9439-49F332D1FE1C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:samsung:exynos_5300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2F9B26D9-AA50-4652-AFC0-A6AC966B4770"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}