« Volver al listado

CVE-2023-30734

Estado: ModificadaMedia (5.5)—

Improper access control vulnerability in Samsung Health prior to version 6.24.3.007 allows attackers to access sensitive information via implicit intent.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-30734",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-30734",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-19T19:35:07.229739Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "mobile.security@samsung.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.5
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "mobile.security@samsung.com",
      "affectedData": [
        {
          "vendor": "Samsung Mobile",
          "product": "Samsung Health",
          "versions": [
            {
              "status": "unaffected",
              "version": "6.24.3.007"
            }
          ],
          "defaultStatus": "affected"
        }
      ]
    }
  ],
  "published": "2023-10-04T04:15:13.127",
  "references": [
    {
      "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023&month=10",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "mobile.security@samsung.com"
    },
    {
      "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023&month=10",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper access control vulnerability in Samsung Health prior to version 6.24.3.007 allows attackers to access sensitive information via implicit intent."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de control de acceso inadecuado en Samsung Health anterior a la versión 6.24.3.007 permite a los atacantes acceder a información confidencial mediante una intención implícita."
    }
  ],
  "lastModified": "2026-06-17T05:55:31.917",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:samsung:health:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A52F47BC-219F-411D-8D1F-609F18F8D9F2",
              "versionEndExcluding": "6.24.3.007"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "mobile.security@samsung.com"
}