A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-28829",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-28829",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-03T01:45:58.400145Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 3.9,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "LOW",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 3.4,
        "exploitabilityScore": 0.5
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMATIC NET PC Software V14",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC NET PC Software V15",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC PCS 7 V8.2",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC PCS 7 V9.0",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC PCS 7 V9.1",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC WinCC",
          "versions": [
            {
              "status": "affected",
              "version": "All versions < V8.0"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SINAUT Software ST7sc",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2023-06-13T09:15:16.707",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-477"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
    }
  ],
  "lastModified": "2026-06-17T05:48:51.483",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:14.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "34A1F08A-1269-44F0-8B10-70A41F9306B2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:15.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "79A56438-47FC-4184-9401-0B859037D0F1"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3EEF9BE1-F6E2-4C05-8020-4D7540882464"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6"
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D7E53AD8-C669-4E1F-9519-4DED57668766",
              "versionEndExcluding": "8.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinaut_st7sc:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B3C162C7-AC9A-44E3-BAE5-1C0D434F264B"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}