The underlying feedback mechanism of
Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N
- Puntuación base: 4.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.38%
- Percentil entre todas las CVEs puntuadas: 30
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-346
- CWE-346
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-2639",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2639",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-01-02T20:56:10.889007Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.3
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.7,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "FactoryTalk System Services",
"versions": [
{
"status": "affected",
"version": "<= 6.20"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-06-13T21:15:10.043",
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-346"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-346"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The underlying feedback mechanism of \n\nRockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. \n\n\n"
}
],
"lastModified": "2026-06-17T05:53:04.537",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_policy_manager:6.11.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "78D6F03E-E110-4CA7-8883-5CE38FF8E5A0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_system_services:6.11.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "46A50229-56B5-4B30-8B4A-6D180D65C2D6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}