« Volver al listado

CVE-2023-25773

Estado: ModificadaAlta (7.8)—

Improper access control in the Intel(R) Unite(R) Hub software installer for Windows before version 4.2.34962 may allow an authenticated user to potentially enable escalation of privilege via local access.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-25773",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-25773",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-10-10T15:37:03.697174Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "secure@intel.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 0.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "secure@intel.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Intel(R) Unite(R) Hub software installer for Windows",
          "versions": [
            {
              "status": "affected",
              "version": "before version 4.2.34962"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-08-11T03:15:18.820",
  "references": [
    {
      "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00826.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "secure@intel.com"
    },
    {
      "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00826.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "secure@intel.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper access control in the Intel(R) Unite(R) Hub software installer for Windows before version 4.2.34962 may allow an authenticated user to potentially enable escalation of privilege via local access."
    }
  ],
  "lastModified": "2026-06-17T05:41:57.620",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:unite:*:*:*:*:*:windows:*:*",
              "vulnerable": true,
              "matchCriteriaId": "20F3A24C-4200-427A-8A82-3247EF4B6BB1",
              "versionEndExcluding": "4.2.34962"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "secure@intel.com"
}