« Back to list

CVE-2023-25549

Status: ModifiedCritical (9.8)—

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint.

Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

CVSS

Exploitation probability (EPSS)

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

Affected technologies (1)

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2023-25549",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-25549",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-03T19:14:12.740311Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "StruxureWare Data Center Expert",
          "versions": [
            {
              "status": "affected",
              "version": "All",
              "versionType": "custom",
              "lessThanOrEqual": "V7.9.2"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-04-18T21:15:08.523",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\nallows for remote code execution when using a parameter of the DCE network settings\nendpoint. \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n"
    }
  ],
  "lastModified": "2026-06-17T05:41:28.153",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9DCD63E5-0A70-47B2-9F4F-5328E0BD04B0",
              "versionEndIncluding": "7.9.2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}