CVE-2023-24552
Estado: ModificadaAlta (7.8)—
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-24552",
"cveTags": [],
"metrics": {
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge SE2022",
"versions": [
{
"status": "affected",
"version": "All versions < V222.0MP12"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2023",
"versions": [
{
"status": "affected",
"version": "All versions < V223.0Update2"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-02-14T11:15:15.137",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process."
}
],
"lastModified": "2026-06-17T05:39:31.590",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "22C0D3BE-0640-49C8-86F1-52966CABA2E2"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DE12CBDF-222E-4DE9-927A-3BDDBFFF1E1A"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EEFAAAE5-52B1-48EA-98E1-98A854CBE65A"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_3:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D5AFCFBB-ED56-4DDB-89D8-B47A20821AB8"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_4:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "087A9E78-9E5C-4D94-A251-02F9AB160F54"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_5:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "68EE0588-FE7F-4581-9484-52404DB5B99A"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_7:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9F72318F-0E9C-4AB1-9CA2-6527513AE0F6"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_8:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "63C93992-17F7-4499-BC57-BD67E8A6C508"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_9:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7180CEA7-150A-4B1D-BDFD-61C320A33148"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_10:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B0244EE5-BF22-491A-A7DE-48F44E2A17FC"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2022:maintenance_pack_11:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3A583AAD-5B13-4822-AA24-AA7D16305FE2"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C",
"versionEndExcluding": "2210.0002.004"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}