CVE-2023-24332
Estado: AnalizadaAlta (8.1)—
A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.55%
- Percentil entre todas las CVEs puntuadas: 44
- Fecha de la puntuación: 7/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-24332",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-24332",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-02-22T15:07:01.343041Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:tendacn:ac6_firmware:03.03.02.01_cn_tdc01:*:*:*:*:*:*:*"
],
"vendor": "tendacn",
"product": "ac6_firmware",
"versions": [
{
"status": "affected",
"version": "03.03.02.01_cn_tdc01"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-02-21T21:15:08.617",
"references": [
{
"url": "https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://github.com/caoyebo/CVE/tree/main/Tenda%20AC6%20-%20CVE-2023-24332",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet."
},
{
"lang": "es",
"value": "Una vulnerabilidad de desbordamiento en la región stack de la memoria en Tenda AC6 con la versión de firmware US_AC6V5.0re_V03.03.02.01_cn_TDC01 permite a los atacantes ejecutar comandos arbitrarios a través de una solicitud POST manipulada para /goform/PowerSaveSet."
}
],
"lastModified": "2026-06-17T05:39:02.110",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac6_firmware:03.03.02.01_cn_tdc01:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "18AE3849-73DE-431E-BF08-43781C87E16E"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac6:5.0:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CFBE582F-BE50-4810-AAB2-B19F40693ACE"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}