CVE-2023-23588
A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 6.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.09%
- Percentil entre todas las CVEs puntuadas: 0
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (4)
CWE
- CWE-200
- CWE-295
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-23588",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-23588",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-10-15T17:09:07.958283Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.2,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 1
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SIMATIC IPC1047",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC1047E",
"versions": [
{
"status": "affected",
"version": "All versions with maxView Storage Manager < 4.09.00.25611 on Windows"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC647D",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC647E",
"versions": [
{
"status": "affected",
"version": "All versions with maxView Storage Manager < 4.09.00.25611 on Windows"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC847D",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC IPC847E",
"versions": [
{
"status": "affected",
"version": "All versions with maxView Storage Manager < 4.09.00.25611 on Windows"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-04-11T10:15:18.097",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\r\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit."
}
],
"lastModified": "2026-06-17T05:37:31.107",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "43337EC1-0BF8-40B3-88BC-38F06EF48DC6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D0EF28FB-BAB3-4710-9D25-25F67ACADC60"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "681C8A24-C3AC-4CF4-8283-DAC337909CC9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "D8F37D88-E086-4060-8420-BD0F8D8FF580"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_ipc1047_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5DA20C3-90EE-4355-99FC-BACE6F77C56C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc1047:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5E959C97-838B-41F6-BD73-AA5073975075"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microchip:maxview_storage_manager:*:*:*:*:*:windows:*:*",
"vulnerable": true,
"matchCriteriaId": "77C02716-54AE-4545-AB8C-4760F92271A2",
"versionEndExcluding": "4.09.00.25611"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc1047e:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "85F2895E-AFB0-4516-B549-93CCD5BB5814"
},
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151"
},
{
"criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}