Estado: ModificadaMedia (6.8)—

Vulnerability in the Oracle Health Sciences InForm product of Oracle Health Sciences Applications (component: Core). Supported versions that are affected are Prior to 6.3.1.3 and Prior to 7.0.0.1. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Health Sciences InForm. Successful attacks require human interaction from a person other than the attacker.

Leer descripción completaMostrar menos

Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle Health Sciences InForm accessible data as well as unauthorized access to critical data or complete access to all Oracle Health Sciences InForm accessible data. CVSS 3.1 Base Score 6.8 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N).

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-21922",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-21922",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-16T19:23:34.811465Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "secalert_us@oracle.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.8,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 1.6
      }
    ]
  },
  "affected": [
    {
      "source": "secalert_us@oracle.com",
      "affectedData": [
        {
          "vendor": "Oracle Corporation",
          "product": "Health Sciences InForm",
          "versions": [
            {
              "status": "affected",
              "version": "*",
              "lessThan": "6.3.1.3",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "*",
              "lessThan": "7.0.0.1",
              "versionType": "semver"
            }
          ]
        }
      ]
    }
  ],
  "published": "2023-04-18T20:15:13.307",
  "references": [
    {
      "url": "https://www.oracle.com/security-alerts/cpuapr2023.html",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "secalert_us@oracle.com"
    },
    {
      "url": "https://www.oracle.com/security-alerts/cpuapr2023.html",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Vulnerability in the Oracle Health Sciences InForm product of Oracle Health Sciences Applications (component: Core).  Supported versions that are affected are Prior to 6.3.1.3 and  Prior to 7.0.0.1. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Health Sciences InForm.  Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in  unauthorized creation, deletion or modification access to critical data or all Oracle Health Sciences InForm accessible data as well as  unauthorized access to critical data or complete access to all Oracle Health Sciences InForm accessible data. CVSS 3.1 Base Score 6.8 (Confidentiality and Integrity impacts).  CVSS Vector: (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N)."
    }
  ],
  "lastModified": "2026-06-17T05:34:20.793",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:health_sciences_inform:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "08A0D91B-E543-48BA-B408-F7FA61B4B35A",
              "versionEndExcluding": "6.3.1.3"
            },
            {
              "criteria": "cpe:2.3:a:oracle:health_sciences_inform:7.0.0.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "51BCEC65-25B7-480C-860C-9D97F78CCE3F"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "secalert_us@oracle.com"
}