CVE-2023-2062
Status: ModifiedMedium (6.2)—
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Base score: 6.2
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.33%
- Percentile among all scored CVEs: 24
- Score date: 10/6/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (4)
CWEs
- CWE-549
- CWE-668
References
Raw JSON (NVD)
Show
{
"id": "CVE-2023-2062",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2062",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-05T18:36:40.253808Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.2,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.2,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.5
}
]
},
"affected": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"affectedData": [
{
"vendor": "Mitsubishi Electric Corporation",
"product": "EtherNet/IP Configuration tool for RJ71EIP91 SW1DNN-EIPCT-BD",
"versions": [
{
"status": "affected",
"version": "Software version \"1.01B\" and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Mitsubishi Electric Corporation",
"product": "EtherNet/IP Configuration tool for FX5-ENET/IP SW1DNN-EIPCTFX5-BD",
"versions": [
{
"status": "affected",
"version": "Software version \"1.01B\" and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-06-02T05:15:10.187",
"references": [
{
"url": "https://jvn.jp/vu/JVNVU92908006",
"tags": [
"Third Party Advisory"
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-157-02",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
},
{
"url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf",
"tags": [
"Vendor Advisory"
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
},
{
"url": "https://jvn.jp/vu/JVNVU92908006",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-004.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"description": [
{
"lang": "en",
"value": "CWE-549"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-668"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP. This vulnerability results in authentication bypass vulnerability, which allows the attacker to access MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP via FTP."
}
],
"lastModified": "2026-06-17T05:51:18.840",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CE006D41-B94B-45A2-B43C-642616811792"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipct-bd_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "98777F49-8CB3-4546-875F-2664224FB52C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipct-bd:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8164854B-5BB1-4936-9BC8-CC78838A47D8"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:rj71eip91_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FF8407A6-F78E-40B8-88D1-D8A824E882F0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:rj71eip91:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0B2B7116-DAC9-4340-A625-93F461E96964"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:sw1dnn-eipctfx5-bd_firmware:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3210B54-8C0E-4A6D-B466-D1FFB3CA5F2A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:sw1dnn-eipctfx5-bd:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B42CE2D9-B4E1-40AD-803F-48FA7C9B4230"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}