CVE-2023-0808
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-259
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-0808",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 3.7,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:H/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "HIGH",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 1.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.9,
"attackVector": "PHYSICAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 0.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "PHYSICAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 0.9
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Deye",
"modules": [
"Access Point Setting Handler"
],
"product": "Inverter",
"versions": [
{
"status": "affected",
"version": "MW3_15U_5406_1.47"
},
{
"status": "affected",
"version": "MW3_15U_5406_1.471"
}
]
},
{
"vendor": "Revolt",
"modules": [
"Access Point Setting Handler"
],
"product": "Inverter",
"versions": [
{
"status": "affected",
"version": "MW3_15U_5406_1.47"
},
{
"status": "affected",
"version": "MW3_15U_5406_1.471"
}
]
},
{
"vendor": "Bosswerk",
"modules": [
"Access Point Setting Handler"
],
"product": "Inverter",
"versions": [
{
"status": "affected",
"version": "MW3_15U_5406_1.47"
},
{
"status": "affected",
"version": "MW3_15U_5406_1.471"
}
]
}
]
}
],
"published": "2023-02-13T12:15:11.467",
"references": [
{
"url": "https://heise.de/-7483376",
"tags": [
"Press/Media Coverage",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.220769",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.220769",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://heise.de/-7483376",
"tags": [
"Press/Media Coverage",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.220769",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.220769",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-259"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability."
}
],
"lastModified": "2026-06-17T05:26:21.290",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:deyeinverter:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AE9B754F-0502-43C0-A105-B586A59CFE07"
},
{
"criteria": "cpe:2.3:o:deyeinverter:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "62BC56BC-7AC1-4EEF-9C33-E3E5B004EDE6"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:deyeinverter:inverter:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CC029D39-994E-4A1C-8E20-B4B1E85472F4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:revolt-power:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "60232246-8FE3-4CE3-9208-7E3E568C779E"
},
{
"criteria": "cpe:2.3:o:revolt-power:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A9B91D9B-F89A-4F02-B12A-358A9D462174"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:revolt-power:inverter:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "975D2DD5-245A-4835-86BC-BED567097279"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosswerk:inverter_firmware:mw3_15u_5406_1.47:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C8E3410F-E68C-46E0-AF50-3A7E95962E70"
},
{
"criteria": "cpe:2.3:o:bosswerk:inverter_firmware:mw3_15u_5406_1.471:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FCBF9CAD-FA2D-413E-986C-AC988AEC758A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosswerk:inverter:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C1C1D833-293C-42B0-A3B9-479001F8E0F6"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}